Difference between revisions of "PRA Information"

From PRA-Info
Jump to navigation Jump to search
 
(53 intermediate revisions by the same user not shown)
Line 1: Line 1:
A list of PRA wikis.
+
EPRI's Risk and Safety Management Program provides on-going research in methods and tools for conducting probabilistic risk assessments (PRAs). Working with experts around the globe, methods are improved by evaluating data and industry experience, developing applied research in numerical and logic modeling techniques, and developing new ways to apply PRAs in a risk-informed framework.
 +
 
 +
Basic information on PRAs as applied throughout the industry is available in the links below.
 +
 
 +
The PRA Applications Wiki is currently only available to EPRI members or members of the EPRI Risk and Safety Management (RSM) program.
  
 
<div class="container" id="pradiv">
 
<div class="container" id="pradiv">
 +
 
<div class="fixed">
 
<div class="fixed">
 +
[[Image:pra1.PNG|link=https://pra-apps.epri.com]]
 
<p class="pralabel">
 
<p class="pralabel">
'''PRA Applications'''</p>
+
'''[https://pra-apps.epri.com PRA Applications Wiki]'''</p>
PRA Applications is a global resource to support nuclear power station personnel in understanding how Probabilistic Risk Assessments, PRAs, can be used to support them.
+
The PRA Applications Wiki provides an introduction to the wide applications of PRA in the nuclear industry. This serves the needs of the global PRA community, providing a clear description, purpose, and rationale for each application.  Both voluntary and regulatory PRA applications are described and this overview distinguishes those that require license-basis changes. References to more technical information provide a resource to expand your knowledge further.
 +
<p class="readmore>
 +
[https://pra-apps.epri.com Read More]
 +
</p>
 +
</div>
  
 +
<div class="fixed">
 +
[[Image:pra2.png|link=https://firepra.epri.com]]
 +
<p class="pralabel">
 +
'''[https://firepra.epri.com Fire PRA Wiki]'''</p>
 +
The Fire PRA Wiki summarizes a structured framework for the conduct of a Fire PRA analysis. This supports your fire risk analysis team by providing an introduction to EPRI 1011989 / NUREG/CR-6850, updated with the latest information. The methodology addresses a Fire PRA that focuses on a Level 1 PRA (Core Damage Frequency) with consideration of Large Early Release Frequency. Additional references to specific recommended practices are provided, which address each key aspect of the analysis.
 +
<br><br>
 +
<p class="readmore>
 +
[https://firepra.epri.com Read More]
 +
</p>
 +
</div>
  
 +
<div class="fixed">
 +
[[Image:pra3.png|link=https://pra-ndm.epri.com]]
 +
<p class="pralabel">
 +
'''[https://pra-ndm.epri.com/  PRA Newly Developed Methods Wiki]'''</p>
 +
With the issuance of Regulatory Guide 1.200, Revision 3 the US Nuclear Regulatory Commission (NRC) endorsed the concept of a “Newly Developed Method (NDM)” for use in Probabilistic Risk Assessments (PRAs). This Wiki shares information from previous evaluations within the industry specifically that have been provided to EPRI for inclusion in the Wiki. These evaluations of interest are those related to whether a PRA method is considered an NDM, and whether an NDM Peer review has been conducted to determine the technical adequacy of the method for inclusion in risk applications as necessary.
 +
<br><br>
 
<p class="readmore>
 
<p class="readmore>
[http://pra-apps.epri.com Read More]
+
[https://pra-ndm.epri.com Read More]
 
</p>
 
</p>
 
</div>
 
</div>
    <div class="fixed">
+
 
 +
<div class="fixed">
 +
[[Image:pra4.png|link=https://externalhazardspra.epri.com]]
 +
<p class="pralabel">
 +
'''[https://externalhazardspra.epri.com External Hazards PRA Wiki]'''</p>
 +
The External Hazards Wiki organizes the nuclear industry's methodologies, regulatory guidance, and operating experience for external hazard assessment into a structured, navigable collection of references and document summaries. The wiki covers multiple hazard types, including high winds, flooding, wildfires, and compound events. This integrated approach provides a practical entry point for professionals new to the field while serving as a consolidated reference for experienced practitioners.
 +
<p class="readmore>
 +
[https://externalhazardspra.epri.com Read More]
 +
</p>
 
</div>
 
</div>
    <div class="fixed">
 
 
</div>
 
</div>
 +
 +
<div class="container" id="pradiv">
 +
 +
<div class="fixed">
 +
[[Image:pra5.jpg|link=https://seismicpra.epri.com]]
 +
<p class="pralabel">
 +
'''[https://seismicpra.epri.com Seismic PRA Wiki]'''</p>
 +
The seismic probabilistic risk assessment (SPRA) Wiki summarizes a structured framework for the conduct of an SPRA analysis. This wiki is intended to serve the needs of a seismic risk analysis team by describing a structured framework for conduct of the overall analysis, as well as providing references to specific recommended practices to address each key aspect of the analysis.  The wiki provides overall guidance, with an emphasis on seismic hazard analysis, SPRA systems analysis, equipment list development, fragility guidance, human reliability analysis, and model development and quantification.
 +
<p class="readmore>
 +
[https://seismicpra.epri.com Read More]
 +
</p>
 
</div>
 
</div>
 +
 +
<div class="fixed">
 +
[[Image:pra6.jpg|link=https://praguidance.epri.com]]
 +
<p class="pralabel">
 +
'''[https://praguidance.epri.com PRA Software Guidance Wiki]'''</p>
 +
This PRA Software Guidance wiki provides recommendations and guidance for using the EPRI PRA software. The EPRI software is designed to be very flexible to support a variety of research in the creating and applying PRA models. In many cases, this diverse set of features can be confusing or can lead to creation of models that cause problems in subsequent applications. Although there is rarely a "best way" to create a PRA model, some techniques will make the software more efficient or enable certain features. This wiki is designed to share these insights with the users.
 +
<p class="readmore>
 +
[https://praguidance.epri.com Read More]
 +
</p>
 +
</div>
 +
 +
<div class="fixed" >
 +
[[Image:pramethods.jpg|link=https://pramethods.epri.com]]
 +
<p class="pralabel">
 +
'''[https://pramethods.epri.com PRA Methods Wiki]'''</p>
 +
Knowledge of the methods used in in the U.S. nuclear industry is in many cases distributed amongst different entities with various degrees of information availability and communication. This wiki provides a centralized, publicly available industry catalog for PRA methods in use.
 +
<p class="readmore>
 +
[https://pramethods.epri.com Read More]
 +
</p>
 +
</div>
 +
 +
<div class="fixed">
 +
[[Image:ramtar.jpg|link=https://ramtar.epri.com]]
 +
<p class="pralabel">
 +
'''[https://ramtar.epri.com Risk Analysis Methods and Tools for Advanced Reactors (RAMTAR) Wiki]'''</p>
 +
Outlines past, present, and future research for advanced reactors by describing a wide range of risk analysis methods and tools that are applicable to various reactor designs, as well as providing references regulations, guidance, and research projects.
 +
<p class="readmore>
 +
[https://ramtar.epri.com Read More]
 +
</p>
 +
</div>
 +
 +
</div>
 +
 +
<div class="container" id="pradiv">
 +
 +
<div class="fixed">
 +
[[Image:prawf.jpg|link=https://pra-workforce.epri.com]]
 +
<p class="pralabel">
 +
'''[https://pra-workforce.epri.com PRA Workforce Wiki]'''</p>
 +
Outlines a plan to develop the PRA workforce by providing a recommended course outline.
 +
This allows users to develop a training plan as well as to review the references to PRA information and training courses available. This material can provide a PRA Engineer with a basis of knowledge for success and supplements the site-specific model training needed to be fully qualified.
 +
<p class="readmore>
 +
[https://pra-workforce.epri.com Read More]
 +
</p>
 +
 +
</div>
 +
 +
<div class="fixed fixedblank"></div>
 +
<div class="fixed fixedblank"></div>
 +
<div class="fixed fixedblank"></div>
 +
 +
</div>
 +
 +
Additional information is available in a wide range of EPRI technical reports at '''[https://www.epri.com/research/programs/061177 Program 41.07.01: Risk and Safety Management]'''.

Latest revision as of 15:42, 18 June 2026

EPRI's Risk and Safety Management Program provides on-going research in methods and tools for conducting probabilistic risk assessments (PRAs). Working with experts around the globe, methods are improved by evaluating data and industry experience, developing applied research in numerical and logic modeling techniques, and developing new ways to apply PRAs in a risk-informed framework.

Basic information on PRAs as applied throughout the industry is available in the links below.

The PRA Applications Wiki is currently only available to EPRI members or members of the EPRI Risk and Safety Management (RSM) program.

Pra1.PNG

PRA Applications Wiki

The PRA Applications Wiki provides an introduction to the wide applications of PRA in the nuclear industry. This serves the needs of the global PRA community, providing a clear description, purpose, and rationale for each application. Both voluntary and regulatory PRA applications are described and this overview distinguishes those that require license-basis changes. References to more technical information provide a resource to expand your knowledge further.

Read More

Pra2.png

Fire PRA Wiki

The Fire PRA Wiki summarizes a structured framework for the conduct of a Fire PRA analysis. This supports your fire risk analysis team by providing an introduction to EPRI 1011989 / NUREG/CR-6850, updated with the latest information. The methodology addresses a Fire PRA that focuses on a Level 1 PRA (Core Damage Frequency) with consideration of Large Early Release Frequency. Additional references to specific recommended practices are provided, which address each key aspect of the analysis.

Read More

Pra3.png

PRA Newly Developed Methods Wiki

With the issuance of Regulatory Guide 1.200, Revision 3 the US Nuclear Regulatory Commission (NRC) endorsed the concept of a “Newly Developed Method (NDM)” for use in Probabilistic Risk Assessments (PRAs). This Wiki shares information from previous evaluations within the industry specifically that have been provided to EPRI for inclusion in the Wiki. These evaluations of interest are those related to whether a PRA method is considered an NDM, and whether an NDM Peer review has been conducted to determine the technical adequacy of the method for inclusion in risk applications as necessary.

Read More

Pra4.png

External Hazards PRA Wiki

The External Hazards Wiki organizes the nuclear industry's methodologies, regulatory guidance, and operating experience for external hazard assessment into a structured, navigable collection of references and document summaries. The wiki covers multiple hazard types, including high winds, flooding, wildfires, and compound events. This integrated approach provides a practical entry point for professionals new to the field while serving as a consolidated reference for experienced practitioners.

Read More

Pra5.jpg

Seismic PRA Wiki

The seismic probabilistic risk assessment (SPRA) Wiki summarizes a structured framework for the conduct of an SPRA analysis. This wiki is intended to serve the needs of a seismic risk analysis team by describing a structured framework for conduct of the overall analysis, as well as providing references to specific recommended practices to address each key aspect of the analysis. The wiki provides overall guidance, with an emphasis on seismic hazard analysis, SPRA systems analysis, equipment list development, fragility guidance, human reliability analysis, and model development and quantification.

Read More

Pra6.jpg

PRA Software Guidance Wiki

This PRA Software Guidance wiki provides recommendations and guidance for using the EPRI PRA software. The EPRI software is designed to be very flexible to support a variety of research in the creating and applying PRA models. In many cases, this diverse set of features can be confusing or can lead to creation of models that cause problems in subsequent applications. Although there is rarely a "best way" to create a PRA model, some techniques will make the software more efficient or enable certain features. This wiki is designed to share these insights with the users.

Read More

Pramethods.jpg

PRA Methods Wiki

Knowledge of the methods used in in the U.S. nuclear industry is in many cases distributed amongst different entities with various degrees of information availability and communication. This wiki provides a centralized, publicly available industry catalog for PRA methods in use.

Read More

Ramtar.jpg

Risk Analysis Methods and Tools for Advanced Reactors (RAMTAR) Wiki

Outlines past, present, and future research for advanced reactors by describing a wide range of risk analysis methods and tools that are applicable to various reactor designs, as well as providing references regulations, guidance, and research projects.

Read More

Prawf.jpg

PRA Workforce Wiki

Outlines a plan to develop the PRA workforce by providing a recommended course outline. This allows users to develop a training plan as well as to review the references to PRA information and training courses available. This material can provide a PRA Engineer with a basis of knowledge for success and supplements the site-specific model training needed to be fully qualified.

Read More

Additional information is available in a wide range of EPRI technical reports at Program 41.07.01: Risk and Safety Management.